Share to:

Engine By Perkins Series is a 50 Hz diesel generator set series from Eastern Lion, built around the Perkins engine, covering 7.2 to 2000 kW in 54 models. It is used for data centres, hospitals, telecommunications, municipal power, construction sites, mining and oil and gas projects.

Engine By Perkins Series

Category: Diesel Generator Set

Key specifications

Power range
7.2 – 2000 kW
Frequency
50 Hz
Models
54
Engine
403A-15G1
Alternator
EL 224G
Controller
Smartgen 6120
Warranty
1 year or 1000 hours
Options
Open frame, silent canopy, trailer, ATS and parallel systems
MOQ
1 set
CSV Datasheet
Genset Specification 400/230V 50HZEngineBrushless AlternatorControllerDatasheet
ModelPrime power (kW)Prime power (kVA)Standby power (kW)Standby power (kVA)Engine modelEngine power (kW)Alternator modelAlternator power (kW)ControllerDatasheet
GFS-P1410131114403A-15G119408El 164C10.8Smartgen 6120Detail
GFS-P1712151317403A-15G219682EL 164D12.8Smartgen 6120Detail
GFS-P2216201822404A-22G122279EL 184E18Smartgen 6120Detail
GFS-P107.29810403D-11G15326EL 164B8.8Smartgen 6120Detail
GFS-P1410.4131214403D-15G20362El 164C10.8Smartgen 6120Detail
GFS-P2216.2201822404D-22G23463EL 184E18Smartgen 6120Detail
GFS-P72526558721104A-44TG138510EL 224F58Smartgen 6120Detail
GFS-P89648071891104A-44TG240024EL 224G68Smartgen 6120Detail
GFS-P67486053671104D-44TG243486EL 224E48Smartgen 6120Detail
GFS-P89648071891104C-44TAG144402EL 224G68Smartgen 6120Detail
GFS-P11180100891111104C-44TAG248139EL 274C80Smartgen 6120Detail
GFS-P89648071891104D-E44TAG158989EL 224G68Smartgen 6120Detail
GFS-P11180100891111104D-E44TAG260552EL 274C80Smartgen 6120Detail
GFS-P1501081351201501106A-70TG154559EL 274E112Smartgen 6120Detail
GFS-P1671201501331671106A-70TAG262576EL 274F128Smartgen 6120Detail
GFS-P2001441801602001106A-70TAG364337EL 274G145.6Smartgen 6120Detail
GFS-P2221602001782221106A-70TAG479193EL 274H160Smartgen 6120Detail
GFS-P1591141431271591106D-E70TAG275330EL 274E112Smartgen 6120Detail
GFS-P1671201501331671106D-E70TAG379447EL 274F128Smartgen 6120Detail
GFS-P2001441801602001106D-E70TAG485914EL 274G145.6Smartgen 6120Detail
GFS-P33243027331103A-33G28246EL 184G25Smartgen 6120Detail
GFS-P50364540501103A-33TG131916EL 224C34Smartgen 6120Detail
GFS-P67486053671103A-33TG237226EL 224E48Smartgen 6120Detail
GFS-P2221602001782221206A-E70TTAG1110277EL 274H160Smartgen 6120Detail
GFS-P2221602001782221206D-E70TTAG1112892EL 274H160Smartgen 6120Detail
GFS-P2561842302042561506A-E88TAG2 L112299EL 274J184Smartgen 6120Detail
GFS-P2561842302042561206A-E70TTAG2114635EL 274J184Smartgen 6120Detail
GFS-P2561842302042561206D-E70TTAG2117360EL 274J184Smartgen 6120Detail
GFS-P2782002502222781506A-E88TAG3 L121647EL 274K200Smartgen 6120Detail
GFS-P2782002502222781206A-E70TTAG3119853EL 274K200Smartgen 6120Detail
GFS-P2782002502222781206D-E70TTAG3122711EL 274K200Smartgen 6120Detail
GFS-P3332403002673331506A-E88TAG5 L145740EL 314D236Smartgen 6120Detail
GFS-P3892803503113892206C-E13TAG2 L165605EL 314FS280Smartgen 6120Detail
GFS-P4443204003564442206C-E13TAG3 L189350EL 314G320Smartgen 6120Detail
GFS-P5063644554045062506C-E15TAG1 L215397EL 354C360Smartgen 6120Detail
GFS-P5564005004445562506C-E15TAG2 L236762EL 354D400Smartgen 6120Detail
GFS-P6674806005336672806C-E18TAG1A L270465EL 354E480Smartgen 6120Detail
GFS-P7225206505787222806A-E18TAG2 L296940EL 354F536Smartgen 6120Detail
GFS-P4443204003564442206D-E13TAG3 L189899EL 314G320Smartgen 6120Detail
GFS-P5564005004445562506D-E15TAG2 L238532EL 354D400Smartgen 6120Detail
GFS-P6674806005336672806D-E18TAG1 L274284.6675EL 354E480Smartgen 6120Detail
GFS-P8336007506678334006-23TAG2A368518.1657EL 354H600Smartgen 6120Detail
GFS-P8896408007118894006-23TAG3A377034.9908EL 404C640Smartgen 6120Detail
GFS-P100072090080010004008TAG1A470565.6161EL 404D728Smartgen 6120Detail
GFS-P1111800100088911114008TAG2474812.9965EL 404E800Smartgen 6120Detail
GFS-P12509001125100012504008-30TAG3531352.8001EL 404F904Smartgen 6120Detail
GFS-P138910001250111113894012-46TWG2A743611.4969EL 404G1000Smartgen 6120Detail
GFS-P150010801350120015004012-46TWG3A800724.9727EL 404G1000Smartgen 6120Detail
GFS-P166712001500133316674012-46TAG2A799831.368EL 404I1240Smartgen 6120Detail
GFS-P190013681710152019004012-46TAG3A873117.9856EL 504D1320Smartgen 6120Detail
GFS-P205614801850164420564016TAG1A1213890.277EL 504E1520Smartgen 6120Detail
GFS-P222216002000177822224016TAG2A1256033.116EL 504F1664Smartgen 6120Detail
GFS-P222216002000177822224016-61TRG21374926.67EL 504F1664Smartgen 6120Detail
GFS-P250018002250200025004016-61TRG31445620.731EL 504G1760Smartgen 6120Detail

Ratings are indicative. Please contact us for the latest datasheet and confirmation of availability.

How to choose this series

Six decisions cover almost every generator set order. Here is how to make each of them — and what this series gives you.

Your decision How to decide it This series
Engine brand The engine decides the spare parts availability and the response time of your local service partner. Compare the service network first, the price second. Perkins — 54 models in this series
Prime or standby Prime is for sets that run 8 to 12 hours a day, standby for emergency backup. Size the set so your load sits at 70 to 80 % of the standby rating — that keeps the engine between 50 % and 75 % load, where the fuel consumption is at its best. Standby 8–2000 kW, prime 7.2–1800 kW
Voltage and frequency 400/230 V at 50 Hz for Asia, Europe, Africa and the Middle East, 230/400 V at 60 Hz for the Americas. The alternator and the control panel both have to match the grid you connect to. 50 Hz, 400/230 V
Enclosure Open frame for a machine room, a silent canopy for an outdoor city site (about 65 dB(A) at 7 m), a container for a 1000 kW block and a trailer for a mobile set. Open frame, silent canopy, trailer and container options
Starting and transfer An emergency set needs electric start and an automatic transfer switch, otherwise the set sits idle until the grid fails. Manual and air start stay available for special duties. Electric start, ATS (automatic and manual) on request
Paralleling More than one set means a power management system, a larger transfer switch and a control panel that lets the sets share the load and take over from each other. Parallel systems with power management
Site conditions Every 1000 m of altitude and every 10 °C above the standard ambient costs about 3 % of the rating, and a salt spray or a dusty site asks for a canopy and a shorter service interval. Standard rating at 0–50 °C, derating on request

Send us the load, the voltage and the site, and we will send back the exact model, the price and the delivery time.

Eastern Lion Perkins series diesel generator sets combine Perkins diesel engines with our own brushless alternators and a reliable control panel. The table below lists the standard 400/230 V, 50 Hz models with prime and standby ratings to ISO 8528. Open frame, silent canopy, trailer, ATS and parallel configurations are available on request.

All generator sets are tested at full load before shipment. Please contact us for a detailed datasheet, pricing and delivery time.

Ratings are indicative. Please contact us for the latest datasheet and confirmation of availability.

Power rangemodelsEngineAlternatorController
Engine By Cummins 2200 – 1311 kW34MTA11-G2AEL 314ESmartgen 6120View details →
Engine By Cummins22 – 444 kW404BTA3.9-G2EL 274KSmartgen 6120View details →
Engine By Huachai Series13 – 289 kW272105DEL 224CRUIFEN6120View details →
Engine By Kofo Series10 – 338 kW24K4100DSEL 184GRUIFEN6120View details →
Engine By Longxin Series24 – 289 kW19R6105IZLDEL 224ERUIFEN6120View details →
Engine By Lovol Series25 – 158 kW131003GEL 274CSmartgen 6120View details →
Engine By Woling Series128 – 889 kW22D114系列WLD171EL 404DSmartgen 6120View details →
Engine By Wuxi Series48 – 1111 kW52WD129TAD23/1500EL 354CSmartgen 6120View details →

Need a generator set for your project?

Tell us the power, voltage and application — our engineers will reply within one working day.